KOHLER automatic transfer switches for homes
The single-phase RXT and RDT automatic transfer switches on KOHLER's switch listing, each with its rating, poles, enclosure and warranty as the two spec sheets give them, and links to those sheets.
About the automatic transfer switches Family
A transfer switch is wired in at the point where the grid supply, the generator and the home's circuits meet. If the grid goes down, it hands the house to the generator, and once the grid is back it hands the house back. The Electrical Safety Authority (ESA) requires a transfer device on every standby generator connected permanently to a home's wiring, since the device keeps the generator's output off the utility's wires.
KOHLER lists two lines of these switches for homes. The RXT takes its orders from the generator and works only with a KOHLER generator that has the RDC2 or DC2 controller. The RDT carries its own MPAC 500 controller on the switch. On both spec sheets the model number spells out the build, and every model in the table is coded for 240 V at 60 Hz, with two poles, a solid neutral and a NEMA 3R aluminum enclosure. Some models add a breaker on the utility side so they can serve as the service entrance, and a few include a load centre for the backed-up circuits.
Models and Specifications
| Model | Rating (A) | Service entrance rated | Poles | Enclosure | Load shedding | Canadian approval | Warranty (years) | Availability | Documents |
|---|---|---|---|---|---|---|---|---|---|
| RXT 200 A, service entranceRXT-JFNC-200ASEQS5 | 200 | Yes | 2-pole, 3-wire, solid neutral | NEMA 3R aluminum | Load shed kit, optional | Not published | 5 | Confirm availability with us | |
| RXT 200 ARXT-JFNC-0200A-QS7 | 200 | No | 2-pole, 3-wire, solid neutral | NEMA 3R aluminum | Load shed kit, optional | Not published | 5 | Confirm availability with us | |
| RXT 100 A, service entranceRXT-JFNC-100ASEQS4 | 100 | Yes | 2-pole, 3-wire, solid neutral | NEMA 3R aluminum | Load shed kit, optional | Not published | 5 | Confirm availability with us | |
| RXT 100 ARXT-JFNC-0100A-QS7 | 100 | No | 2-pole, 3-wire, solid neutral | NEMA 3R aluminum | Load shed kit, optional | Not published | 5 | Confirm availability with us | |
| RXT 400 A, service entranceRXT-JFNC-400ASEQS3 | 400 | Yes | 2-pole, 3-wire, solid neutral | NEMA 3R aluminum | Load shed kit, optional | Not published | 5 | Confirm availability with us | |
| RXT 400 ARXT-JFNC-0400A-QS4 | 400 | No | 2-pole, 3-wire, solid neutral | NEMA 3R aluminum | Load shed kit, optional | Not published | 5 | Confirm availability with us | |
| RXT 100 A, 16-space load centreRXT-JFNC-0100B-QS4 | 100 | No | 2-pole, 3-wire, solid neutral | NEMA 3R aluminum | Not published | Not published | 5 | Confirm availability with us | |
| RXT 100 A, service entrance, CSARXT-JFNC-100CSEQS3 | 100 | Yes | 2-pole, 3-wire, solid neutral | NEMA 3R aluminum | Load shed kit, optional | CSA | 5 | Listed for Canada by KOHLER | |
| RXT 150 A, service entranceRXT-JFNC-150ASEQS3 | 150 | Yes | 2-pole, 3-wire, solid neutral | NEMA 3R aluminum | Load shed kit, optional | Not published | 5 | Confirm availability with us | |
| RXT 200 A, service entrance, CSARXT-JFNC-200CSEQS3 | 200 | Yes | 2-pole, 3-wire, solid neutral | NEMA 3R aluminum | Load shed kit, optional | CSA | 5 | Listed for Canada by KOHLER | |
| RXT 300 A, service entranceRXT-JFNC-300ASEQS4 | 300 | Yes | 2-pole, 3-wire, solid neutral | NEMA 3R aluminum | Load shed kit, optional | Not published | 5 | Confirm availability with us | |
| RXT 400 A, CSARXT-JFNC-400A-MV07 | 400 | No | 2-pole, 3-wire, solid neutral | NEMA 3R aluminum | Load shed kit, optional | CSA | 5 | Listed for Canada by KOHLER | |
| RXT 400 A, service entrance, CSARXT-JFNC-400CSEQS | 400 | Yes | 2-pole, 3-wire, solid neutral | NEMA 3R aluminum | Load shed kit, optional | CSA | 5 | Listed for Canada by KOHLER | |
| RDT 200 A, service entranceRDT-CFNC-200ASEQS4 | 200 | Yes | 2-pole, 3-wire, solid neutral | NEMA 3R aluminum | Load shed kit, optional | Not published | 5 | Confirm availability with us | |
| RDT 200 A, service entrance, 42-space load centreRDT-CFNC-200BSEQS3 | 200 | Yes | 2-pole, 3-wire, solid neutral | NEMA 3R aluminum | Not published | Not published | 5 | Confirm availability with us | |
| RDT 200 ARDT-CFNC-0200A-QS7 | 200 | No | 2-pole, 3-wire, solid neutral | NEMA 3R aluminum | Load shed kit, optional | Not published | 5 | Confirm availability with us | |
| RDT 100 ARDT-CFNC-0100A-QS7 | 100 | No | 2-pole, 3-wire, solid neutral | NEMA 3R aluminum | Load shed kit, optional | Not published | 5 | Confirm availability with us | |
| RDT 200 A, load centreRDT-CFNC-0200B-QS7 | 200 | No | 2-pole, 3-wire, solid neutral | NEMA 3R aluminum | Not published | Not published | 5 | Confirm availability with us | |
| RDT 400 ARDT-CFNC-400A-QS10 | 400 | No | 2-pole, 3-wire, solid neutral | NEMA 3R aluminum | Load shed kit, optional | Not published | 5 | Confirm availability with us | |
| RDT 400 A, CSARDT-CFNC-400A-QS11 | 400 | No | 2-pole, 3-wire, solid neutral | NEMA 3R aluminum | Load shed kit, optional | CSA | 5 | Listed for Canada by KOHLER | |
| RDT 400 A, service entranceRDT-CFNC-400ASEQS5 | 400 | Yes | 2-pole, 3-wire, solid neutral | NEMA 3R aluminum | Load shed kit, optional | Not published | 5 | Confirm availability with us |
Specifications checked against KOHLER's published documents on 2026-10-01. Figures are the manufacturer's and can change; the linked documents are the source.
Canadian Context
Five of these switches have CSA in the name KOHLER's listing gives them, and the table lists those five for Canada. The other sixteen names print no Canadian mark, so they read Confirm availability with us. Both spec sheets say CSA certification can be had on some versions, and the RXT sheet adds that it must be chosen when the switch is ordered. We check the mark on the exact model number before ordering a switch for a home here.
On a service entrance model the utility side runs through a disconnect breaker inside the switch, which lets the switch take the place of the main breaker next to the meter. That work happens at the meter itself, so the local utility cuts the supply before it starts and restores it after. ESA requires a notification of work for any generator wired permanently into a house, and ESA's advice is to have a licensed electrical contractor install it.
The Electrical Safety Authority (ESA) notification of work is filed before the work starts. When the installation is done, ESA inspects it and issues a Certificate of Acceptance once it passes. Where the unit burns natural gas or propane, a licensed gas fitter makes the gas connection. Where a meter or a service entrance switch is involved, the local utility does its part of the work.
automatic transfer switches Documents
RDT automatic transfer switch spec sheet
Spec sheet, English
Hosted by KOHLER
For: RDT 200 A, service entrance, RDT 200 A, service entrance, 42-space load centre, RDT 200 A, RDT 100 A, RDT 200 A, load centre, RDT 400 A, RDT 400 A, CSA, RDT 400 A, service entrance
Open the PDFRXT automatic transfer switch spec sheet
Spec sheet, English
Hosted by KOHLER
For: RXT 200 A, service entrance, RXT 200 A, RXT 100 A, service entrance, RXT 100 A, RXT 400 A, service entrance, RXT 400 A, RXT 100 A, 16-space load centre, RXT 100 A, service entrance, CSA, RXT 150 A, service entrance, RXT 200 A, service entrance, CSA, RXT 300 A, service entrance, RXT 400 A, CSA, RXT 400 A, service entrance, CSA
Open the PDFFrequently Asked Questions
The RXT is run by the generator. It works only with a KOHLER generator that has the RDC2 or DC2 controller, and that controller handles the transfer and can show the utility voltage. The RDT has its own MPAC 500 controller on the switch, with LED fault lights, a test button and a weekly exercise of 20 minutes. Both lines are two-pole switches for a 240 V home service.