KOHLER automatic transfer switches for homes

The single-phase RXT and RDT automatic transfer switches on KOHLER's switch listing, each with its rating, poles, enclosure and warranty as the two spec sheets give them, and links to those sheets.

4.9 Stars

145+ Google Reviews

ESA Licensed Electrical Contractor

ESA Licence #7018179

Licensed & insured

Remarkable Electric BBB Business Review

A+ Rating

💰

Flat-Rate Pricing

Quoted upfront, no surprises

🛡️

Lifetime Warranty

Satisfaction guaranteed

About the automatic transfer switches Family

A transfer switch is wired in at the point where the grid supply, the generator and the home's circuits meet. If the grid goes down, it hands the house to the generator, and once the grid is back it hands the house back. The Electrical Safety Authority (ESA) requires a transfer device on every standby generator connected permanently to a home's wiring, since the device keeps the generator's output off the utility's wires.

KOHLER lists two lines of these switches for homes. The RXT takes its orders from the generator and works only with a KOHLER generator that has the RDC2 or DC2 controller. The RDT carries its own MPAC 500 controller on the switch. On both spec sheets the model number spells out the build, and every model in the table is coded for 240 V at 60 Hz, with two poles, a solid neutral and a NEMA 3R aluminum enclosure. Some models add a breaker on the utility side so they can serve as the service entrance, and a few include a load centre for the backed-up circuits.

Models and Specifications

KOHLER automatic transfer switches: every current model, figures from KOHLER's published documents
ModelRating (A)Service entrance ratedPolesEnclosureLoad sheddingCanadian approvalWarranty (years)AvailabilityDocuments
RXT 200 A, service entranceRXT-JFNC-200ASEQS5200Yes2-pole, 3-wire, solid neutralNEMA 3R aluminumLoad shed kit, optionalNot published5Confirm availability with us
RXT 200 ARXT-JFNC-0200A-QS7200No2-pole, 3-wire, solid neutralNEMA 3R aluminumLoad shed kit, optionalNot published5Confirm availability with us
RXT 100 A, service entranceRXT-JFNC-100ASEQS4100Yes2-pole, 3-wire, solid neutralNEMA 3R aluminumLoad shed kit, optionalNot published5Confirm availability with us
RXT 100 ARXT-JFNC-0100A-QS7100No2-pole, 3-wire, solid neutralNEMA 3R aluminumLoad shed kit, optionalNot published5Confirm availability with us
RXT 400 A, service entranceRXT-JFNC-400ASEQS3400Yes2-pole, 3-wire, solid neutralNEMA 3R aluminumLoad shed kit, optionalNot published5Confirm availability with us
RXT 400 ARXT-JFNC-0400A-QS4400No2-pole, 3-wire, solid neutralNEMA 3R aluminumLoad shed kit, optionalNot published5Confirm availability with us
RXT 100 A, 16-space load centreRXT-JFNC-0100B-QS4100No2-pole, 3-wire, solid neutralNEMA 3R aluminumNot publishedNot published5Confirm availability with us
RXT 100 A, service entrance, CSARXT-JFNC-100CSEQS3100Yes2-pole, 3-wire, solid neutralNEMA 3R aluminumLoad shed kit, optionalCSA5Listed for Canada by KOHLER
RXT 150 A, service entranceRXT-JFNC-150ASEQS3150Yes2-pole, 3-wire, solid neutralNEMA 3R aluminumLoad shed kit, optionalNot published5Confirm availability with us
RXT 200 A, service entrance, CSARXT-JFNC-200CSEQS3200Yes2-pole, 3-wire, solid neutralNEMA 3R aluminumLoad shed kit, optionalCSA5Listed for Canada by KOHLER
RXT 300 A, service entranceRXT-JFNC-300ASEQS4300Yes2-pole, 3-wire, solid neutralNEMA 3R aluminumLoad shed kit, optionalNot published5Confirm availability with us
RXT 400 A, CSARXT-JFNC-400A-MV07400No2-pole, 3-wire, solid neutralNEMA 3R aluminumLoad shed kit, optionalCSA5Listed for Canada by KOHLER
RXT 400 A, service entrance, CSARXT-JFNC-400CSEQS400Yes2-pole, 3-wire, solid neutralNEMA 3R aluminumLoad shed kit, optionalCSA5Listed for Canada by KOHLER
RDT 200 A, service entranceRDT-CFNC-200ASEQS4200Yes2-pole, 3-wire, solid neutralNEMA 3R aluminumLoad shed kit, optionalNot published5Confirm availability with us
RDT 200 A, service entrance, 42-space load centreRDT-CFNC-200BSEQS3200Yes2-pole, 3-wire, solid neutralNEMA 3R aluminumNot publishedNot published5Confirm availability with us
RDT 200 ARDT-CFNC-0200A-QS7200No2-pole, 3-wire, solid neutralNEMA 3R aluminumLoad shed kit, optionalNot published5Confirm availability with us
RDT 100 ARDT-CFNC-0100A-QS7100No2-pole, 3-wire, solid neutralNEMA 3R aluminumLoad shed kit, optionalNot published5Confirm availability with us
RDT 200 A, load centreRDT-CFNC-0200B-QS7200No2-pole, 3-wire, solid neutralNEMA 3R aluminumNot publishedNot published5Confirm availability with us
RDT 400 ARDT-CFNC-400A-QS10400No2-pole, 3-wire, solid neutralNEMA 3R aluminumLoad shed kit, optionalNot published5Confirm availability with us
RDT 400 A, CSARDT-CFNC-400A-QS11400No2-pole, 3-wire, solid neutralNEMA 3R aluminumLoad shed kit, optionalCSA5Listed for Canada by KOHLER
RDT 400 A, service entranceRDT-CFNC-400ASEQS5400Yes2-pole, 3-wire, solid neutralNEMA 3R aluminumLoad shed kit, optionalNot published5Confirm availability with us

Specifications checked against KOHLER's published documents on 2026-10-01. Figures are the manufacturer's and can change; the linked documents are the source.

Canadian Context

Five of these switches have CSA in the name KOHLER's listing gives them, and the table lists those five for Canada. The other sixteen names print no Canadian mark, so they read Confirm availability with us. Both spec sheets say CSA certification can be had on some versions, and the RXT sheet adds that it must be chosen when the switch is ordered. We check the mark on the exact model number before ordering a switch for a home here.

On a service entrance model the utility side runs through a disconnect breaker inside the switch, which lets the switch take the place of the main breaker next to the meter. That work happens at the meter itself, so the local utility cuts the supply before it starts and restores it after. ESA requires a notification of work for any generator wired permanently into a house, and ESA's advice is to have a licensed electrical contractor install it.

The Electrical Safety Authority (ESA) notification of work is filed before the work starts. When the installation is done, ESA inspects it and issues a Certificate of Acceptance once it passes. Where the unit burns natural gas or propane, a licensed gas fitter makes the gas connection. Where a meter or a service entrance switch is involved, the local utility does its part of the work.

automatic transfer switches Documents

RDT automatic transfer switch spec sheet

Spec sheet, English

Hosted by KOHLER

For: RDT 200 A, service entrance, RDT 200 A, service entrance, 42-space load centre, RDT 200 A, RDT 100 A, RDT 200 A, load centre, RDT 400 A, RDT 400 A, CSA, RDT 400 A, service entrance

Open the PDF

RXT automatic transfer switch spec sheet

Spec sheet, English

Hosted by KOHLER

For: RXT 200 A, service entrance, RXT 200 A, RXT 100 A, service entrance, RXT 100 A, RXT 400 A, service entrance, RXT 400 A, RXT 100 A, 16-space load centre, RXT 100 A, service entrance, CSA, RXT 150 A, service entrance, RXT 200 A, service entrance, CSA, RXT 300 A, service entrance, RXT 400 A, CSA, RXT 400 A, service entrance, CSA

Open the PDF

More documents on KOHLER's site →

Frequently Asked Questions

Ask Us About automatic transfer switches

Sizing, quote and installation by licensed electricians

This is for

*By clicking Get a Free Quote, I consent to receive marketing prerecorded and automated calls from Remarkable Electric at the phone number provided. By providing your phone number above and checking this box, you agree to receive automated text messages from Remarkable Electric and also agree to our Terms of Use and Privacy Policy. Consent is not a condition of purchase, message frequency will vary. Message and data rates may apply. Unsubscribe to text messages at any time by replying STOP or calling us at (289) 210-5221. For questions or assistance reply HELP.

Call Us

(289) 210-5221

Service Area

Hamilton, Niagara & Southern Ontario

Hours

Open 24 hours, 7 days a week

Our Promise

Satisfaction Guaranteed or We Come Back Free