Champion air-cooled home standby generators
This page lists the Champion home standby bundles marked for Canada, each an air-cooled generator sold with its own automatic transfer switch, with the figures Champion publishes for every model. They come in three lines, Select Circuit, aXis and fleX, and all of them run on natural gas or propane.
About the home standby generators Family
Every Champion home standby generator on its listing is a bundle: an air-cooled unit sold together with an automatic transfer switch. The listing groups them into three lines. The two Select Circuit units are the smallest, at 8.5 kW and 12.5 kW on propane, and their 50 A or 100 A switch backs up a fixed number of circuits. The aXis and fleX bundles use a switch rated for service entrance work, from 100 A to 200 A, which can carry the whole house.
The aXis line comes in 14 kW and 22 kW, and the fleX line in 10, 18, 22 and 26 kW. Both lines take Champion's load management modules, sold separately. The modules let you give household loads up to four priority levels, or keep a large appliance off while the generator is running. Champion measures sound at 23 ft, and the units in this table read 59.5 to 67 dB(A).
Models and Specifications
| Model | Output on propane (kW) | Output on natural gas (kW) | Fuel | Engine (cc) | Transfer switch (A) | Load management | Sound level at 23 ft (7 m) (dBA) | Warranty (years) | Cold weather kit | Certifications | Dimensions (mm) | Weight (kg) | Availability | Documents |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Select Circuit 8.5 kW, 50 A switch100177 | 8.5 | 7.5 | Natural gas or propane | 439 | 50 | No | 59.5 | 10 | No | cULus; EPA certified | 1245 x 711 x 711 mm | 170 | Listed for Canada by Champion |
|
| Select Circuit 12.5 kW, 100 A switch100179 | 12.5 | 11 | Natural gas or propane | 717 | 100 | No | 63 | 10 | No | cULus; EPA certified | 1245 x 711 x 711 mm | 193 | Listed for Canada by Champion |
|
| aXis 14 kW, 100 A switch100838 | 14 | 12.5 | Natural gas or propane | 754 | 100 | aXis load management module 100868, sold separately | 62 | 10 | Not published | cETL; EPA certified | 1245 x 711 x 711 mm | 199 | Listed for Canada by Champion | |
| aXis 14 kW, 200 A switch100839 | 14 | 12.5 | Natural gas or propane | 754 | 200 | aXis load management module 100868, sold separately | 62 | 10 | Not published | cETL; EPA certified | 1245 x 711 x 711 mm | 199 | Listed for Canada by Champion | |
| aXis 22 kW, 100 A switch201219 | 22 | 19.8 | Natural gas or propane | 999 | 100 | aXis load management module 100868, sold separately | 67 | 10 | Not published | cETLus; EPA certified | 1346 x 716 x 721 mm | 268 | Listed for Canada by Champion | |
| aXis 22 kW, 200 A switch201221 | 22 | 19.8 | Natural gas or propane | 999 | 200 | aXis load management module 100868, sold separately | 67 | 10 | Not published | cETLus; EPA certified | 1346 x 716 x 721 mm | 268 | Listed for Canada by Champion | |
| fleX 10 kW, 100 A switch201595 | 10 | 9 | Natural gas or propane | 500 | 100 | Yes, with load management modules | 61 | 10 | Not published | cETLus; EPA certified | 1059 x 655 x 640 mm | 139 | Listed for Canada by Champion | |
| fleX 10 kW, 200 A switch201597 | 10 | 9 | Natural gas or propane | 500 | 200 | Yes, with load management modules | 61 | 10 | Not published | cETLus; EPA certified | 1059 x 655 x 640 mm | 139 | Listed for Canada by Champion | |
| fleX 18 kW, 200 A switch201566 | 18 | 16.2 | Natural gas or propane | 999 | 200 | fleX load management module 201019, sold separately | 67 | 10 | Not published | cETLus; CSA listed; EPA certified | 1430 x 711 x 724 mm | 236 | Listed for Canada by Champion | |
| fleX 22 kW, 100 A switch201010 | 22 | 19.8 | Natural gas or propane | 999 | 100 | fleX load management module 201019, sold separately | 67 | 10 | Not published | cETLus; EPA certified | 1430 x 711 x 711 mm | 254 | Listed for Canada by Champion | |
| fleX 22 kW, 200 A switch201016 | 22 | 19.8 | Natural gas or propane | 999 | 200 | fleX load management module 201019, sold separately | 67 | 10 | Not published | cETLus; EPA certified | 1430 x 711 x 711 mm | 254 | Listed for Canada by Champion | |
| fleX 26 kW, 100 A switch201612 | 26 | 23.4 | Natural gas or propane | 999 | 100 | fleX load management module 201019 | 67 | 10 | Not published | cETLus; EPA certified | 1430 x 711 x 724 mm | 262 | Listed for Canada by Champion | |
| fleX 26 kW, 150 A switch201613 | 26 | 23.4 | Natural gas or propane | 999 | 150 | fleX load management module 201019 | 67 | 10 | Not published | cETLus; EPA certified | 1430 x 711 x 724 mm | 262 | Listed for Canada by Champion | |
| fleX 26 kW, 200 A switch201614 | 26 | 23.4 | Natural gas or propane | 999 | 200 | fleX load management module 201019 | 67 | 10 | Not published | cETLus; EPA certified | 1430 x 711 x 724 mm | 262 | Listed for Canada by Champion |
Specifications checked against Champion's published documents on 2026-10-01. Figures are the manufacturer's and can change; the linked documents are the source.
Canadian Context
Champion's listing puts a small flag on each bundle for the country it is sold in, and every row in this table carries the Canadian flag. Its sizing page says Champion builds separate home standby models for Canada and for the United States. The eight bundles that show only the US flag are left out. The certifications column gives the mark each product page prints: cETLus on most rows, cETL on the two 14 kW aXis bundles and cULus on the two Select Circuit units.
Champion rates each unit twice, once on propane and once on natural gas, and the natural gas figure is lower. The 22 kW units drop to 19.8 kW on natural gas and the 26 kW units to 23.4 kW, so a house on the gas main should be sized from the natural gas column. Champion says the 24 V starting system works down to -22 °F, which is -30 °C. Only the Select Circuit pages add that no warming kit is needed, so the cold weather column reads Not published on the other rows.
The fact sheets list the aXis and fleX switches in 100 A and 200 A versions under a CSA service entrance rating. Fitting a switch like that between the meter and the panel usually means the utility has to disconnect the service while the work is done. Before the job, the electrical contractor files a notification of work with the Electrical Safety Authority (ESA), which then inspects the installation. A licensed gas fitter runs the gas line to the unit.
The Electrical Safety Authority (ESA) notification of work is filed before the work starts. When the installation is done, ESA inspects it and issues a Certificate of Acceptance once it passes. Where the unit burns natural gas or propane, a licensed gas fitter makes the gas connection. Where a meter or a service entrance switch is involved, the local utility does its part of the work.
home standby generators Documents
aXis 14 and 22 kW fact sheet
Spec sheet, English
Hosted by Champion
For: aXis 14 kW, 100 A switch, aXis 14 kW, 200 A switch, aXis 22 kW, 100 A switch, aXis 22 kW, 200 A switch
Open the PDFfleX 22 kW fact sheet
Spec sheet, English
Hosted by Champion
For: fleX 22 kW, 100 A switch, fleX 22 kW, 200 A switch
Open the PDFfleX 26 kW fact sheet
Spec sheet, English
Hosted by Champion
For: fleX 26 kW, 100 A switch, fleX 26 kW, 150 A switch, fleX 26 kW, 200 A switch
Open the PDFSelect Circuit 8.5 kW operator's manual
Owner's manual, English
Hosted by Champion
For: Select Circuit 8.5 kW, 50 A switch
Open the PDFSelect Circuit 8.5 kW operator's manual, French
Owner's manual, French
Hosted by Champion
For: Select Circuit 8.5 kW, 50 A switch
Open the PDFSelect Circuit 12.5 kW operator's manual
Owner's manual, English
Hosted by Champion
For: Select Circuit 12.5 kW, 100 A switch
Open the PDFSelect Circuit 12.5 kW operator's manual, French
Owner's manual, French
Hosted by Champion
For: Select Circuit 12.5 kW, 100 A switch
Open the PDFaXis 14 kW operator's manual
Owner's manual, English
Hosted by Champion
For: aXis 14 kW, 100 A switch, aXis 14 kW, 200 A switch
Open the PDFaXis 14 kW operator's manual, French
Owner's manual, French
Hosted by Champion
For: aXis 14 kW, 100 A switch, aXis 14 kW, 200 A switch
Open the PDFfleX 22 kW operator's manual
Owner's manual, English
Hosted by Champion
For: fleX 22 kW, 100 A switch, fleX 22 kW, 200 A switch
Open the PDFfleX 22 kW operator's manual, French
Owner's manual, French
Hosted by Champion
For: fleX 22 kW, 100 A switch, fleX 22 kW, 200 A switch
Open the PDFaXis 22 kW operator's manual
Owner's manual, English
Hosted by Champion
For: aXis 22 kW, 100 A switch, aXis 22 kW, 200 A switch
Open the PDFaXis 22 kW operator's manual, French
Owner's manual, French
Hosted by Champion
For: aXis 22 kW, 100 A switch, aXis 22 kW, 200 A switch
Open the PDFfleX 18 kW operator's manual
Owner's manual, English
Hosted by Champion
For: fleX 18 kW, 200 A switch
Open the PDFfleX 18 kW operator's manual, French
Owner's manual, French
Hosted by Champion
For: fleX 18 kW, 200 A switch
Open the PDFfleX 10 kW operator's manual
Owner's manual, English
Hosted by Champion
For: fleX 10 kW, 100 A switch, fleX 10 kW, 200 A switch
Open the PDFfleX 10 kW operator's manual, French
Owner's manual, French
Hosted by Champion
For: fleX 10 kW, 100 A switch, fleX 10 kW, 200 A switch
Open the PDFfleX 26 kW operator's manual
Owner's manual, English
Hosted by Champion
For: fleX 26 kW, 100 A switch, fleX 26 kW, 150 A switch, fleX 26 kW, 200 A switch
Open the PDFfleX 26 kW operator's manual, French
Owner's manual, French
Hosted by Champion
For: fleX 26 kW, 100 A switch, fleX 26 kW, 150 A switch, fleX 26 kW, 200 A switch
Open the PDFSelect Circuit generator installation manual
Installation manual, English
Hosted by Champion
For: Select Circuit 8.5 kW, 50 A switch, Select Circuit 12.5 kW, 100 A switch
Open the PDFSelect Circuit generator installation manual, French
Installation manual, French
Hosted by Champion
For: Select Circuit 8.5 kW, 50 A switch, Select Circuit 12.5 kW, 100 A switch
Open the PDFSelect Circuit transfer switch selector installation manual
Installation manual, English
Hosted by Champion
For: Select Circuit 8.5 kW, 50 A switch, Select Circuit 12.5 kW, 100 A switch
Open the PDFSelect Circuit installation rough-in guide
Installation manual, English
Hosted by Champion
For: Select Circuit 8.5 kW, 50 A switch, Select Circuit 12.5 kW, 100 A switch
Open the PDFSelect Circuit transfer switch installation manual, back fuse version
Installation manual, English
Hosted by Champion
For: Select Circuit 8.5 kW, 50 A switch, Select Circuit 12.5 kW, 100 A switch
Open the PDFSelect Circuit transfer switch installation manual, front fuse version
Installation manual, English
Hosted by Champion
For: Select Circuit 8.5 kW, 50 A switch, Select Circuit 12.5 kW, 100 A switch
Open the PDFaXis generator installation manual
Installation manual, English
Hosted by Champion
For: aXis 14 kW, 100 A switch, aXis 14 kW, 200 A switch, aXis 22 kW, 100 A switch, aXis 22 kW, 200 A switch
Open the PDFaXis generator installation manual, French
Installation manual, French
Hosted by Champion
For: aXis 14 kW, 100 A switch, aXis 14 kW, 200 A switch, aXis 22 kW, 100 A switch, aXis 22 kW, 200 A switch
Open the PDFaXis transfer switch installation manual
Installation manual, English
Hosted by Champion
For: aXis 14 kW, 100 A switch, aXis 14 kW, 200 A switch, aXis 22 kW, 100 A switch, aXis 22 kW, 200 A switch
Open the PDFaXis transfer switch installation manual, French
Installation manual, French
Hosted by Champion
For: aXis 14 kW, 100 A switch, aXis 14 kW, 200 A switch, aXis 22 kW, 100 A switch, aXis 22 kW, 200 A switch
Open the PDFfleX transfer switch installation manual
Installation manual, English
Hosted by Champion
For: fleX 10 kW, 100 A switch, fleX 10 kW, 200 A switch, fleX 18 kW, 200 A switch, fleX 22 kW, 100 A switch, fleX 22 kW, 200 A switch, fleX 26 kW, 100 A switch, fleX 26 kW, 150 A switch
Open the PDFfleX transfer switch installation manual, French
Installation manual, French
Hosted by Champion
For: fleX 10 kW, 100 A switch, fleX 10 kW, 200 A switch, fleX 18 kW, 200 A switch, fleX 22 kW, 100 A switch, fleX 22 kW, 200 A switch, fleX 26 kW, 100 A switch, fleX 26 kW, 150 A switch
Open the PDFfleX generator installation manual
Installation manual, English
Hosted by Champion
For: fleX 10 kW, 100 A switch, fleX 10 kW, 200 A switch, fleX 18 kW, 200 A switch, fleX 22 kW, 100 A switch, fleX 22 kW, 200 A switch, fleX 26 kW, 100 A switch, fleX 26 kW, 150 A switch
Open the PDFfleX generator installation manual, French
Installation manual, French
Hosted by Champion
For: fleX 10 kW, 100 A switch, fleX 10 kW, 200 A switch, fleX 18 kW, 200 A switch, fleX 22 kW, 100 A switch, fleX 22 kW, 200 A switch, fleX 26 kW, 100 A switch, fleX 26 kW, 150 A switch
Open the PDFHome standby generator warranty
Warranty, English
Hosted by Champion
For: Select Circuit 8.5 kW, 50 A switch, Select Circuit 12.5 kW, 100 A switch, aXis 14 kW, 100 A switch, aXis 14 kW, 200 A switch, aXis 22 kW, 100 A switch, aXis 22 kW, 200 A switch, fleX 10 kW, 100 A switch, fleX 10 kW, 200 A switch, fleX 18 kW, 200 A switch, fleX 22 kW, 100 A switch, fleX 22 kW, 200 A switch, fleX 26 kW, 100 A switch, fleX 26 kW, 150 A switch, fleX 26 kW, 200 A switch
Open the PDFFrequently Asked Questions
Roughly a tenth on most units. Champion rates its 22 kW units at 19.8 kW on natural gas, the 26 kW units at 23.4 kW and the 14 kW aXis units at 12.5 kW. The 8.5 kW Select Circuit unit gives 7.5 kW. If your house is on the gas main, size the generator from the natural gas figure.
Champion rates the 24 V starting system for temperatures as low as -22 °F, which is -30 °C. Its Select Circuit pages state that no warming kit is needed. The aXis and fleX pages give the same starting temperature but say nothing about a kit, so ask us about your unit before its first winter.
The amp rating is the most current the switch can carry. The Select Circuit bundles come with a 50 A or 100 A switch that powers a fixed group of 12 or 16 circuits. The aXis and fleX bundles come with a service entrance switch of 100 A, 150 A or 200 A, which sits between the meter and the main panel and can carry the whole house.
It can. Champion's fact sheets give the gas each unit burns. The 22 kW fleX unit uses 207.7 cubic feet of natural gas an hour at half load and 292.6 at full load, and the 26 kW unit 321.1 at full load. A long pipe run or a small meter may not keep up. A licensed gas fitter checks the meter, the pipe size and the run, and replaces what cannot carry the load.
Ask Us About home standby generators
Call Us
(289) 210-5221Service Area
Hamilton, Niagara & Southern Ontario
Hours
Open 24 hours, 7 days a week
Our Promise
Satisfaction Guaranteed or We Come Back Free