Generac manual transfer switches
Generac's manual transfer switches connect a portable generator to a home through a cord and a switch wired in by a licensed electrician, feeding either chosen circuits or the whole panel. The table lists each switch Generac shows on its listings today, with the figures from its spec sheets and links to its documents.
About the manual transfer switches Family
Generac lists these switches in two places. Two HomeLink models sit with its standby generator transfer switches, and five more are on its page of transfer switches for portable generators. A HomeLink switch arrives pre-wired with breakers for a group of essential circuits, and the generator cord connects through an L14-30 inlet. Generac's spec sheet says a HomeLink switch can later be converted to work with a Generac home standby generator of up to 11 kW. The other five include a two-circuit outdoor switch, two single-load switches and two whole-house switches.
The enclosure decides where each switch goes and how the cord reaches it. The HomeLink and single-load switches have indoor enclosures (NEMA 1), so the generator cord plugs into a power inlet box on an outside wall. The two-circuit and whole-house switches have outdoor enclosures (NEMA 3R) with the cord inlet on the bottom of the box. A single-load switch feeds one load, such as a well pump, or a subpanel. Generac's spec sheets describe the single-load and whole-house switches as suitable for service entrance equipment.
Models and Specifications
| Model | Rating (A) | Circuits | Inlet type | Listing | Location | Warranty (years) | Availability | Documents |
|---|---|---|---|---|---|---|---|---|
| HomeLink 30 AG0068521 | 30 | 8 | L14-30 | Not published | Indoor (NEMA 1) | 5 | Confirm availability with us | |
| HomeLink 30 A with resin power inlet boxG0068531 | 30 | 8 | L14-30 | Not published | Indoor (NEMA 1) | 5 | Confirm availability with us | |
| Single load 100 AG0063341 | 100 | Not published | Not published | Not published | Indoor (NEMA 1) | 2 | Confirm availability with us | |
| Single load 60 AG0063331 | 60 | Not published | Not published | Not published | Indoor (NEMA 1) | 2 | Confirm availability with us | |
| 30 A, one or two circuitsG0063771 | 30 | 2 | L14-30 | Not published | Outdoor (NEMA 3R) | 2 | Confirm availability with us | |
| Whole house 200 A utility, 30 A generatorG0063821 | 200 | 12 | L14-30 | Not published | Outdoor (NEMA 3R) | 2 | Confirm availability with us | |
| Whole house 200 A utility, 50 A generatorG0063351 | 200 | 12 | CS6365 | Not published | Outdoor (NEMA 3R) | 2 | Confirm availability with us |
Specifications checked against Generac's published documents on 2026-10-01. Figures are the manufacturer's and can change; the linked documents are the source.
Canadian Context
The Electrical Safety Authority (ESA) says a generator wired permanently into a home needs a transfer device, which keeps generator power from flowing back into the utility system. Power fed back through a panel puts line workers and neighbours at risk, so a cord run from a generator into a wall outlet is never a safe way to connect. Connecting a generator permanently needs a notification of work filed with ESA, and ESA recommends hiring a licensed electrical contractor for the installation. ESA also advises checking the generator and its parts for the mark of a recognized certification agency.
None of the seven product pages shows a Canadian mark, so each row asks you to confirm availability with us. A whole-house switch used as service entrance equipment sits between the meter and the main panel, and the utility has to disconnect and reconnect the service while it goes in. A GenerLink, which fits behind the electricity meter, is the other common way to connect a portable generator, and it also needs a short meter pull arranged with the utility. With any of these switches, the generator's 240 V outlet has to match the switch's inlet, such as an L14-30 on a 30 A switch.
The Electrical Safety Authority (ESA) notification of work is filed before the work starts. When the installation is done, ESA inspects it and issues a Certificate of Acceptance once it passes. Where the unit burns natural gas or propane, a licensed gas fitter makes the gas connection. Where a meter or a service entrance switch is involved, the local utility does its part of the work.
manual transfer switches Documents
Single-load 60 A and 100 A switches spec sheet
Spec sheet, English
Hosted by Generac
For: Single load 100 A, Single load 60 A
Open the PDF30 A two-circuit switch spec sheet
Spec sheet, English
Hosted by Generac
For: 30 A, one or two circuits
Open the PDFWhole-house 200 A switches spec sheet
Spec sheet, English
Hosted by Generac
For: Whole house 200 A utility, 30 A generator, Whole house 200 A utility, 50 A generator
Open the PDFHomeLink 30 A switches spec sheet
Spec sheet, English
Hosted by Generac
For: HomeLink 30 A, HomeLink 30 A with resin power inlet box
Open the PDFHomeLink switch owner's manual
Owner's manual, English
Hosted by Generac
For: HomeLink 30 A, HomeLink 30 A with resin power inlet box
Open the PDFSingle-load switches installation guidelines
Installation manual, English
Hosted by Generac
For: Single load 100 A, Single load 60 A
Open the PDF30 A two-circuit switch installation and operating instructions
Installation manual, English
Hosted by Generac
For: 30 A, one or two circuits
Open the PDFWhole-house 200 A switches installation guidelines
Installation manual, English
Hosted by Generac
For: Whole house 200 A utility, 30 A generator, Whole house 200 A utility, 50 A generator
Open the PDFHomeLink switch five-year limited warranty
Warranty, English
Hosted by Generac
For: HomeLink 30 A, HomeLink 30 A with resin power inlet box
Open the PDFFrequently Asked Questions
Generac's product pages give a starting size for each switch. The HomeLink, single-load and two-circuit switches list portable generators from 5 kW, and the HomeLink and two-circuit switches call for a 30 A outlet. The whole-house switch built for a 30 A generator also starts at 5 kW, while its 50 A version starts at 8 kW with a 50 A outlet. Beyond those minimums, the loads you want to run decide the size.
Yes. A gas furnace, a well pump and an electric water heater are wired in, so an extension cord cannot reach them, and a transfer switch is how they run on generator power. Generac's pages name these loads for the HomeLink, single-load and two-circuit switches. Your electrician moves each chosen circuit onto the switch, and during an outage you start the generator and make the transfer by hand.